{"id":12432,"date":"2024-06-29T17:27:17","date_gmt":"2024-06-29T10:27:17","guid":{"rendered":"https:\/\/serverhot.vn\/product\/uncategorized\/thiet-bi-mang-cisco-catalyst-1000-c1000-24fp-4g-l-ma-san-pham-c1000-24fp-4g-l\/"},"modified":"2024-06-29T17:27:18","modified_gmt":"2024-06-29T10:27:18","slug":"thiet-bi-mang-cisco-catalyst-1000-c1000-24fp-4g-l-ma-san-pham-c1000-24fp-4g-l","status":"publish","type":"product","link":"https:\/\/serverhot.vn\/en\/-product-\/thiet-bi-mang-cisco-catalyst-1000-c1000-24fp-4g-l-ma-san-pham-c1000-24fp-4g-l\/","title":{"rendered":"Thi\u1ebft B\u1ecb M\u1ea1ng Cisco Catalyst 1000 C1000-24FP-4G-L M\u00e3 s\u1ea3n ph\u1ea9m: C1000-24FP-4G-L"},"content":{"rendered":"<div class=\"showText tabs\" id=\"tab2\">\n<div class=\"box_right_pro_view\">\n<div class=\"thongso_pro a_technical\" style=\"max-height: fit-content\">\n<h2><strong>Th\u00f4ng s\u1ed1 k\u1ef9 thu\u1eadt Switch Cisco C1000-24FP-4G-L<\/strong><\/h2>\n<table border=\"1\" cellspacing=\"0\" cellpadding=\"0\">\n<thead>\n<tr>\n<td>\n<p><strong>Description<\/strong><\/p>\n<\/td>\n<td>\n<p><strong>Performance<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\"><strong>Hardware<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Interface<\/td>\n<td>24x 10\/100\/1000 Ethernet PoE+ ports and 370W PoE budget, 4x 1G SFP uplinks<\/td>\n<\/tr>\n<tr>\n<td>Console ports<\/td>\n<td>\n<ul>\n<li>1x RJ-45 Ethernet<\/li>\n<li>USB mini-B<\/li>\n<li>USB-A port for storage and Bluetooth console<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<tr>\n<td>Indicator LEDs<\/td>\n<td>\n<ul>\n<li>Per-port status: link integrity, disabled, activity<\/li>\n<li>System status: system<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<tr>\n<td>Dimensions (WxDxH in inches)<\/td>\n<td>17.5 x 13.59 x 1.73<\/td>\n<\/tr>\n<tr>\n<td>Weight<\/td>\n<td>4.6<\/td>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td colspan=\"2\">\n<p><strong>Memory and processor<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>CPU<\/p>\n<\/td>\n<td>\n<p>ARM v7 800 MHz<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>DRAM<\/p>\n<\/td>\n<td>\n<p>512 MB<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Flash memory<\/p>\n<\/td>\n<td>\n<p>256 MB<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p><strong>Performance<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Forwarding bandwidth<\/p>\n<\/td>\n<td>\n<p>28 Gbps<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Switching bandwidth<\/p>\n<\/td>\n<td>\n<p>56 Gbps<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Forwarding rate<br \/>(64\u2011byte L3 packets)<\/p>\n<\/td>\n<td>\n<p>41.67 Mpps<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Unicast MAC addresses<\/p>\n<\/td>\n<td>\n<p>15,360<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>IPv4 unicast direct routes<\/p>\n<\/td>\n<td>\n<p>542<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>IPv4 unicast indirect routes<\/p>\n<\/td>\n<td>\n<p>256<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>IPv6 unicast direct routes<\/p>\n<\/td>\n<td>\n<p>414<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>IPv6 unicast indirect routes<\/p>\n<\/td>\n<td>\n<p>128<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>IPv4 static routes<\/p>\n<\/td>\n<td>\n<p>16<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>IPv6 static routes<\/p>\n<\/td>\n<td>\n<p>16<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>IPv4 multicast routes and IGMP groups<\/p>\n<\/td>\n<td>\n<p>1024<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>IPv6 multicast groups<\/p>\n<\/td>\n<td>\n<p>1024<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>IPv4\/MAC security ACEs<\/p>\n<\/td>\n<td>\n<p>600<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>IPv6 security ACEs<\/p>\n<\/td>\n<td>\n<p>600<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Maximum active VLANs<\/p>\n<\/td>\n<td>\n<p>256<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>VLAN IDs available<\/p>\n<\/td>\n<td>\n<p>4094<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Maximum STP instances<\/p>\n<\/td>\n<td>\n<p>64<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>Maximum SPAN sessions<\/td>\n<td>4<\/td>\n<\/tr>\n<tr>\n<td>MTU-L3 packet<\/td>\n<td>9198 bytes<\/td>\n<\/tr>\n<tr>\n<td>Jumbo Ethernet frame<\/td>\n<td>10,240 bytes<\/td>\n<\/tr>\n<tr>\n<td>Ingress protection<\/td>\n<td>IP20<\/td>\n<\/tr>\n<tr>\n<td>Dying Gasp<\/td>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">\n<p><strong>Electrical<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>Power<\/td>\n<td>\n<p>Use the supplied AC power cord to connect the AC power connector to an AC power outlet<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>Voltage (auto ranging)<\/td>\n<td>110 to 220V AC in<\/td>\n<\/tr>\n<tr>\n<td>Frequency<\/td>\n<td>50 to 60 Hz<\/td>\n<\/tr>\n<tr>\n<td>Current<\/td>\n<td>0.21A to 0.26A<\/td>\n<\/tr>\n<tr>\n<td>Power rating (maximum consumption)<\/td>\n<td>0.24 kVA<\/td>\n<\/tr>\n<tr>\n<td>PoE Suports<\/td>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<td>Total PoE Suports<\/td>\n<td>370W<\/td>\n<\/tr>\n<tr>\n<td>PoE Power<\/td>\n<td>30W for any 12 or 15W for 24 ports<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\"><strong>Safety and compliance<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Safety<\/td>\n<td>UL 60950-1 Second Edition, CAN\/CSA-C22.2 No. 60950-1 Second Edition, EN 60950-1 Second Edition, IEC 60950-1 Second Edition, AS\/NZS 60950-1<\/td>\n<\/tr>\n<tr>\n<td>EMC: Emissions<\/td>\n<td>47CFR Part 15 (CFR 47) Class A, AS\/NZS CISPR22 Class A, CISPR22 Class A, EN55022 Class A, ICES003 Class A, VCCI Class A, EN61000-3-2, EN61000-3-3, KN22 Class A, CNS13438 Class A<\/td>\n<\/tr>\n<tr>\n<td>EMC: Immunity<\/td>\n<td>EN55024 (including EN 61000-4-5), CISPR24, EN300386, KN24<\/td>\n<\/tr>\n<tr>\n<td>Environmental<\/td>\n<td>Reduction of Hazardous Substances (RoHS) including Directive 2011\/65\/EU<\/td>\n<\/tr>\n<tr>\n<td>Telco<\/td>\n<td>Common Language Equipment Identifier (CLEI) code<\/td>\n<\/tr>\n<tr>\n<td>U.S. government certifications<\/td>\n<td>TBD<\/td>\n<\/tr>\n<\/tbody>\n<\/table><\/div>\n<p>                            <!--                            <\/p>\n<div class=\"xemthem_id_r\">--><br \/>\n                            <!--                                <a><!--\/show\/?token=--><br \/>\n                            <!--\"--><br \/>\n                            <!--                                   class=\"preview fancybox fancybox.ajax\" rel=\"nofollow\"&gt;Xem th&#234;m th&#244;ng s&#7889; k&#7929; thu&#7853;t<\/a>--><br \/>\n                            <!--                            <\/div>\n<p>-->\n                        <\/p><\/div>\n<\/p><\/div>","protected":false},"excerpt":{"rendered":"<ul>\n<p><span style=\"color: #333333;font-family: OpenSansRegular;font-size: 14px;background-color: #ffffff\">C1000-24FP-4G-L Catalyst 1000 24 port GE, Full POE, 4x1G SFP \u25cf 24x 10\/100\/1000 Ethernet PoE+ ports and 370W PoE budget \u25cf 4x 1G SFP uplinks \u25cf Over-the-air Bluetooth access<\/span><\/p>\n<\/ul>","protected":false},"featured_media":12433,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"pwb-brand":[],"product_cat":[2893],"product_tag":[2847,25,2849],"class_list":{"0":"post-12432","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-cisco","7":"product_tag-cisco","8":"product_tag-man","9":"product_tag-switch","11":"first","12":"instock","13":"shipping-taxable","14":"product-type-simple"},"brands":[],"_links":{"self":[{"href":"https:\/\/serverhot.vn\/en\/wp-json\/wp\/v2\/product\/12432","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/serverhot.vn\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/serverhot.vn\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/serverhot.vn\/en\/wp-json\/wp\/v2\/comments?post=12432"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/serverhot.vn\/en\/wp-json\/wp\/v2\/media\/12433"}],"wp:attachment":[{"href":"https:\/\/serverhot.vn\/en\/wp-json\/wp\/v2\/media?parent=12432"}],"wp:term":[{"taxonomy":"pwb-brand","embeddable":true,"href":"https:\/\/serverhot.vn\/en\/wp-json\/wp\/v2\/pwb-brand?post=12432"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/serverhot.vn\/en\/wp-json\/wp\/v2\/product_cat?post=12432"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/serverhot.vn\/en\/wp-json\/wp\/v2\/product_tag?post=12432"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}